Dental Equipment · Endodontics

Woodpecker Endo Radar Pro – Precision Dental Motor Tool Set

$557
Integrated motor and apex locator: combines a brushless endodontic motor with a real-time electronic apex locator, allowing simultaneous canal shaping and working-length monitoring without switching devices.:
Auto Torque Reverse (ATR): automatically reverses file movement when the preset torque limit is reached, reducing the risk of file separation during instrumentation.:
100 to 2500 rpm wide speed range: supports conventional and high-speed rotary file systems as well as reciprocating instrumentation with adjustable angles from 20 to 400 degrees.:
Compact 9.7 mm contra-angle head: ultra-small head with 360-degree rotation improves visibility and access in the posterior quadrant during complex endodontic procedures.:
Top Highlights
Brand / Model
Woodpecker Endo Radar Pro
Motor Type
Brushless
Speed Range
100 to 2500 rpm
Torque Range
0.4 to 5.0 Ncm
Reciprocating Angle
20 to 400 degrees (10-degree increments)
Contra-Angle Head
9.7 mm · 360-degree rotation
Gear Ratio
6:1
Intended Use
Endodontic Motor + Apex Locator (Rx)
Quality
CE Marked, ISO 13485
Buy Now
Guaranteed Safe And Secure Checkout
Visa Mastercard American Express Discover PayPal PayU Razorpay Stripe

The Woodpecker Endo Radar Pro is an integrated endodontic system combining a brushless rotary motor with a built-in electronic apex locator, allowing simultaneous canal preparation and real-time working-length monitoring from a single device. A wide speed range of 100 to 2500 rpm accommodates most modern NiTi file systems, and the fully adjustable reciprocating angle (20 to 400 degrees in 10-degree increments) supports both rotary and reciprocating instrumentation techniques. The compact 9.7 mm contra-angle head with 360-degree rotation improves access to posterior teeth. Auto Torque Reverse (ATR) continuously monitors file resistance and automatically changes motor movement when the preset torque limit is exceeded, providing a practical safeguard against instrument separation. A cordless brushless handpiece, capacitive touchscreen, and 11 pre-loaded file system presets complete a system designed to reduce procedural complexity and improve endodontic workflow efficiency.

2500 rpm max speed
5.0 Ncm max torque
400° Max reciprocating angle
9.7 mm contra-angle head

Key features

1 Integrated Apex Locator

Real-time file position tracking during rotary or reciprocating instrumentation, eliminating the need to swap to a separate apex locator unit.

2 Auto Torque Reverse (ATR)

Continuously monitors torque and automatically reverses file movement at the preset limit to reduce the risk of instrument separation.

3 Brushless Motor

Delivers smooth, efficient performance with lower heat generation and less operating noise compared to conventional brushed motors.

4 11 File System Presets

Pre-loaded operating modes for common NiTi file systems allow immediate clinical use. All parameters are fully customizable.

Motor Type Brushless
Speed Range 100 to 2500 rpm
Torque Range 0.4 to 5.0 Ncm
Reciprocating Angle 20 to 400 degrees (10-degree increments)
Gear Ratio 6:1
Contra-Angle Head Size 9.7 mm
Contra-Angle Rotation 360 degrees
Battery Rechargeable Lithium (base unit and handpiece)
File System Presets 11 pre-loaded programs
Display Capacitive Touchscreen
ATR Auto Torque Reverse, preset threshold

The Woodpecker Endo Radar Pro is CE certified and manufactured under an ISO 13485:2016 certified quality management system for medical devices. It is a genuine Woodpecker product supplied through SnapShopHub as an export distributor, which operates under its own ISO 13485-certified distribution quality management system. It is intended exclusively for professional dental use.

CE Certified European conformity for medical devices
ISO 13485:2016 Medical device quality management system
1
Connect Apex Cables: Attach the measuring wire and secure the lip hook to the patient's oral mucosa to establish the apex locator circuit.
2
Load the File: Insert the selected rotary or reciprocating NiTi file into the 6:1 contra-angle head and verify it is securely seated.
3
Select Mode and Presets: Choose a pre-loaded file system program or set custom speed, torque, and reciprocating angle on the touchscreen.
4
Advance Under Monitoring: Advance the file into the canal while watching the real-time apex position indicator and torque reading on the LCD display.
5
Allow ATR to Activate: If resistance exceeds the preset torque threshold, ATR automatically reverses or changes file movement to protect the instrument.
6
Confirm and Continue: Stop at the confirmed working length and proceed with the remaining canal preparation and obturation per clinical protocol.
endo radar
  • 1 x Apex Locator Base Unit
  • 1 x Cordless Brushless Handpiece
  • 1 x 6:1 Contra-Angle (9.7 mm head)
  • 1 x Protective Silicone Cover
  • 1 x Power Adapter
  • 1 x USB Charging Cable
  • Set: Apex Locator Cable Set (Measuring Wire, File Clips, Lip Hooks, Touch Probes)
  • Kit: Accessory Kit: Apex Tester, Lubricator, Disposable Insulation Sleeves, O-Rings
  • 1 x User Manual

Clinicians

Endodontists General Dentists Oral Surgeons

Settings

Endodontic Practices General Dental Clinics Dental Hospitals Dental Colleges

Procedures

Rotary Root Canal Preparation Glide Path Preparation Reciprocating Instrumentation Working Length Determination Calcified Canal Management Endodontic Retreatment
Sterilize After Each Patient

Autoclave the contra-angle, file clips, and lip hooks after every procedure. Wipe the handpiece and base unit with approved surface disinfectants.

Lubricate the Contra-Angle

Lubricate the contra-angle gears regularly to maintain smooth operation and prolong the service life of the handpiece.

Charge Regularly

Store the cordless handpiece on its charging base between procedures to maintain battery readiness. Both the base unit and handpiece have independent lithium batteries.

Inspect Accessories

Check file clips, lip hooks, and the measuring wire periodically for signs of wear or damage and replace as recommended.

Professional use only: This is a prescription-grade professional endodontic device intended exclusively for use by qualified dental professionals. Endodontic motor-driven instrumentation carries inherent procedural risks including file separation. The ATR function reduces but does not eliminate this risk. Always autoclave the contra-angle, file clips, and lip hooks between patients. Use the measuring wire only with approved surface disinfectants. Follow current infection control guidelines and local regulatory requirements for your destination market. Regulatory and compliance documentation available on request before purchase.

Questions

Frequently Asked Questions

The Endo Radar Pro integrates a real-time electronic apex locator directly into the motor system, enabling simultaneous canal shaping and working-length monitoring without switching devices. A standard endodontic motor drives files but does not track file position relative to the apical constriction.
ATR continuously monitors the resistance encountered by the file during instrumentation. When torque reaches the clinician's preset limit, the motor automatically reverses or changes file movement to relieve stress on the instrument. This reduces but does not eliminate the risk of file separation.
The system includes 11 pre-loaded operating programs for common NiTi rotary and reciprocating file systems. Speed, torque, and reciprocating angle parameters can be fully customized, making the motor compatible with most modern NiTi file systems on the market.
Yes. The reciprocating mode allows the operator to adjust the alternating angle from 20 to 400 degrees in 10-degree increments, supporting a wide variety of single-file and reciprocating NiTi techniques.
A cordless handpiece provides greater freedom of movement around the patient, improved tactile feedback during instrumentation, and reduced operator fatigue during extended endodontic procedures compared to tethered handpieces.
The contra-angle, file clips, and lip hooks are autoclavable and should be sterilized between patients. The measuring wire and the handpiece body should be cleaned with approved clinical surface disinfectants only.
Bulk Enquiry