Diagnostics · Point-of-Care Coagulation Testing

Qlabs Q-3 PT INR Self Testing Analyzer for Home Use Monitor

$429
Rapid PT/INR testing: delivers results in approximately 30 to 100 seconds for timely anticoagulation monitoring.::
Low blood sample requirement: only 10 µL of capillary blood needed for more comfortable routine testing.::
Built-in quality control: automatically detects testing errors and invalidates compromised results to improve reliability.::
Portable rechargeable design: compact analyzer with rechargeable battery, USB power, and carrying pouch for home or professional use.::
Top Highlights
Brand
Micropoint
Model
qLabs Q-3
Device Type
Point-of-Care PT/INR Analyzer
Intended Use
Home & Professional PT/INR Monitoring
Detection Range
0.5 to 8.0 INR
Sample Volume
10 µL Capillary Whole Blood
Result Time
30 to 100 Seconds
Memory
Up to 2,000 Patient Records
Power
Rechargeable Battery & USB
Quality
CE marked, ISO 13485
Buy Now
Guaranteed Safe And Secure Checkout
Visa Mastercard American Express Discover PayPal PayU Razorpay Stripe

The qLabs Q-3 is a compact point-of-care coagulation analyzer designed for patients on oral anticoagulant therapy and healthcare professionals requiring rapid PT/INR testing. A 10 µL capillary blood sample delivers results in 30 to 100 seconds across a 0.5 to 8.0 INR range, supporting routine anticoagulation management at home and in professional settings.

30–100s Result time
10 µL Sample volume
2,000 Patient records
0.5–8.0 INR detection range

Key features

1 Rapid PT/INR Results

Results in 30 to 100 seconds from a fingerstick capillary sample.

2 10 µL Sample Volume

Minimal blood requirement for more comfortable routine testing.

3 Auto Quality Control

Built-in QC detects errors and prevents invalid results from displaying.

4 2,000 Record Memory

Stores up to 2,000 patient records for long-term monitoring.

5 Calibration-Free

Automatically reads coding from compatible test strips, no manual setup.

6 Rechargeable Portable

Battery and USB power plus carrying pouch for home and travel use.

Product Name qLabs Q-3 PT INR Self Testing Analyzer
Brand Micropoint
Model qLabs Q-3
Device Type Point-of-Care Coagulation Analyzer
Test Performed PT / INR
Detection Range 0.5 to 8.0 INR
Sample Type Capillary Whole Blood
Sample Volume 10 µL
Result Time 30 to 100 Seconds
Display High-Contrast Digital Colour LCD
Memory Up to 2,000 Patient Records
Power Source Rechargeable Battery & USB Power
Usage Home & Clinical Use
Design Compact Handheld Analyzer

The QLabs Q-3 PT-INR Self-Testing Analyzer is designed according to applicable medical device quality and safety standards. The QLabs PT-INR testing system is CE marked, while the manufacturer operates under ISO 13485-certified quality management systems. Any additional regulatory approvals or certifications should be confirmed against the documentation supplied with the specific Q-3 model.

CE marked
ISO 13485
1
Prepare: Wash your hands with warm water and switch on the analyzer.
2
Insert Strip: Insert a compatible qLabs PT/INR test strip into the meter.
3
Collect: Use the reusable lancing device with a new sterile lancet to obtain a fresh fingertip blood sample.
4
Apply: Place approximately 10 µL of blood onto the test strip as instructed.
5
Measure: Wait while the analyzer processes the sample and displays the PT/INR result.
6
Record: Review the result and store or document it for future monitoring and healthcare appointments.
Important: Always use genuine qLabs test strips to ensure proper quality control and accurate results. Do not use third-party strips with this analyzer.
pt inr analyser
  • 1 x Micropoint qLabs Q-3 Analyzer
  • 1 x Reusable Lancet Device
  • 1 x Carrying Pouch
  • 1 x Power Adapter
  • 1 x USB Charging Cable

Settings

Home Monitoring Physician Clinics Hospitals Outpatient Facilities Anticoagulation Clinics Community Healthcare

Users

Warfarin Patients Anticoagulation Patients Nurses (Home Visits) Healthcare Professionals

Use Cases

Routine PT/INR Monitoring Anticoagulation Management Point-of-Care Coagulation Testing Travel Monitoring

PT and INR values measure how quickly blood clots, helping healthcare professionals monitor patients on oral anticoagulant medications such as warfarin and determine whether treatment stays within the prescribed therapeutic range

  • qLabs PT/INR Test Strips Required for every test. Sold separately.
  • Disposable Sterile Lancets For fingerstick blood collection. Single use only.
  • Reusable Lancet Device Included with the analyzer for sample collection.
  • qLabs e-Station Dock Data transfer and printing.
Authorized Strips Only

Use only authorized qLabs test strips. Third-party strips may produce unreliable results.

Store Strips Correctly

Store test strips according to the manufacturer's storage instructions.

New Lancet Every Time

Use a new sterile lancet for every test. Do not reuse lancets or test strips.

Keep Clean and Dry

Keep the analyzer clean and dry. Avoid exposure to extreme temperatures or moisture.

Recharge Regularly

Recharge the battery regularly to ensure the analyzer is ready at all times.

Follow Provider Guidance

Always follow your healthcare provider's guidance when interpreting PT/INR results.

Medical disclaimer PT/INR results from this analyzer are intended to assist in anticoagulation monitoring and should always be interpreted in consultation with a qualified healthcare professional. Never adjust anticoagulant medication dosage based solely on home test results without first consulting your healthcare provider. A QC error result means the test is invalid and should be repeated with a new strip and fresh blood sample.

Questions

Frequently Asked Questions

It is suitable for patients receiving oral anticoagulant therapy as well as healthcare professionals performing point-of-care PT/INR testing.
No. The analyzer automatically reads coding information from compatible qLabs test strips, eliminating manual calibration.
No. Compatible qLabs PT/INR test strips are sold separately and must be purchased alongside the analyzer.
Yes. The analyzer may be shared, provided each user uses a new sterile lancet and a new compatible test strip for every individual test.
Only approximately 10 µL of capillary whole blood is required for each measurement.
Discard the current test strip, insert a new compatible strip, and repeat the test using a fresh blood sample.
Yes. Its compact size, rechargeable battery, and carrying pouch make it well suited for travel and nurse home visits.
Yes. It stores up to 2,000 patient records, allowing long-term PT/INR history review directly on the device.
Results can be viewed directly on the analyzer. The optional qLabs e-Station dock, available separately, enables data transfer and printing.
Genuine qLabs test strips ensure proper quality control, reliable analyzer performance, and accurate PT/INR measurements. Third-party strips are not compatible.
Bulk Enquiry