Therapy Equipments · Ultrasonic Therapy

Digital Ultrasound Device 1-3MHz Pain Relief Machine

$149.50
Three separate digital displays: the ULTR 52 Pro features individual green digital readouts for session time (minutes), treatment mode, and output intensity in W/cm² - each on its own display for clear, unambiguous parameter monitoring during treatment.::::::::::
Four output modes with selector probe: Continuous (CONT.), Pulse A, Pulse B, and Wave modes are selectable via dedicated buttons, with the active mode shown on the central digital display. The selector probe button allows probe switching mid-session.::::::::::
Intensity W/cm² bar graph and digital display: output intensity is shown both as a precise digital readout in W/cm² and as a bar-graph indicator for visual reference during probe application.::::::::::
Error, 1 MHz, and 3 MHz LED status indicators: three dedicated LED indicators on the right panel confirm active probe frequency, alert to poor coupling or probe errors, and provide at-a-glance system status during all sessions.::::::::::
Top Highlights
Model
ULTR 52 Pro (Advanced Ultrasound Therapy)
Frequencies
1 MHz and 3 MHz (separate output ports)
Output modes
Continuous (CONT.), Pulse A, Pulse B, Wave
Displays
3 individual digital displays: time (min), mode, intensity (W/cm²)
Intensity indicator
Digital W/cm² readout plus bar-graph display
Status LEDs
Error, 1 MHz, 3 MHz indicator LEDs
Power supply
Mains AC (110V / 220V, 50/60 Hz)
Certifications
ISO 13485 and CE marked, documentation available
Buy Now
Guaranteed Safe And Secure Checkout
Visa Mastercard American Express Discover PayPal PayU Razorpay Stripe

The ULTR 52 Pro is an advanced digital ultrasound therapy device providing 1 MHz and 3 MHz treatment frequencies through separate labelled output ports. Three individual digital displays show session time, treatment mode, and output intensity in W/cm² simultaneously and independently, eliminating the ambiguity of combined or scrolling parameter displays. Four output modes including Continuous, Pulse A, Pulse B, and Wave cover the full spectrum of acute, sub-acute, and chronic clinical applications. Designed for home wellness and personal therapy use as well as clinical settings, the unit is straightforward to operate with logically grouped controls for Time, Mode/Selector Probe, and Intensity. Error, 1 MHz, and 3 MHz LED indicators on the right panel provide real-time system status throughout every session.

3 displays Time, mode, intensity (W/cm²)
1 + 3 MHz Dual probe frequencies
4 modes Cont, Pulse A, Pulse B, Wave
ISO & CE Marked and documented

Key features

1 Three independent digital displays

Separate green digital readouts for time (minutes), mode, and intensity (W/cm²) make it easy to monitor all session parameters simultaneously without sharing a single screen.

2 Four output modes

Continuous output delivers uninterrupted ultrasonic energy. Pulse A and Pulse B modes provide pulsed waveforms at different duty cycles. Wave mode adds a modulated output for additional clinical flexibility.

3 Intensity W/cm² with bar graph

Output intensity is shown as a precise digital value in W/cm² on the right display, accompanied by a bar-graph indicator for quick visual reference during active probe application.

4 Error, 1 MHz, and 3 MHz LED indicators

Three right-panel LEDs confirm active probe frequency, alert to poor acoustic coupling or disconnected probes via the Error LED, and provide instant system status feedback throughout treatment.

5 Selector probe button

The Selector Probe button on the Mode panel switches the active output between the connected 1 MHz and 3 MHz probes without powering off or reconnecting cables.

6 Time up/down control

Dedicated up and down buttons on the Time panel allow session duration to be set and adjusted in the unit of minutes, with the countdown shown on the left digital display.

7 Intensity up/down control

Separate intensity up and down buttons on the right panel provide precise incremental adjustment of output level during active treatment without requiring probe lift-off.

8 Home wellness and personal use design

The ULTR 52 Pro is specifically designed for home wellness and personal therapy applications in addition to clinical use, with intuitive controls and clear displays suited to informed personal therapy programmes.

Model ULTR 52 Pro (Advanced Ultrasound Therapy 1 & 3 MHz)
Device type Digital dual-frequency ultrasound therapy unit
Frequencies 1 MHz and 3 MHz (separate labelled output ports)
Output modes Continuous (CONT.), Pulse A, Pulse B, Wave
Displays 3 separate digital displays: left (time/min), centre (mode), right (intensity W/cm²)
Intensity indicator Digital W/cm² readout plus bar-graph visual indicator
Status LEDs Error LED, 1 MHz LED, 3 MHz LED (right panel)
Probe selector Front-panel selector probe button (Mode section)
Timer Adjustable via Time up/down buttons; countdown on left display
Power supply Mains AC, 110V / 220V, 50/60 Hz
Enclosure Desktop unit with side probe holders
Intended use Home wellness, personal therapy, and professional clinical settings
ControlFunction
Power button Switches the unit on or off from the mains supply
Time display (left) Green digital display showing the current session timer value in minutes
Time up button Increases the session duration setting
Time down button Decreases the session duration setting
Mode display (centre) Green digital display showing the currently active output mode
CONT. button Selects continuous output mode for uninterrupted ultrasound delivery
PULSE A button Selects Pulse A pulsed output mode at a defined duty cycle
PULSE B button Selects Pulse B pulsed output mode at an alternative duty cycle
WAVE button Selects Wave modulated output mode
Mode up / Mode down buttons Navigate through mode options when using the mode buttons
Selector Probe button Switches the active output between the 1 MHz and 3 MHz probe ports
Selector Probe left / right buttons Navigate probe selection options
Intensity display (right) Green digital display showing the current output intensity in W/cm²
Intensity bar graph Visual bar indicator of relative output intensity level
Intensity up button Increases the output intensity in incremental steps
Intensity down button Decreases the output intensity in incremental steps
ERROR LED Illuminates on poor acoustic coupling, probe disconnection, or system fault
1 MHz LED Illuminates when the 1 MHz probe is the active output frequency
3 MHz LED Illuminates when the 3 MHz probe is the active output frequency
1 MHz output port Front-panel socket for the 1 MHz probe cable connection
3 MHz output port Front-panel socket for the 3 MHz probe cable connection
Condition / AreaApplication / Protocol
Muscle and joint pain relief 1 MHz for deeper musculature and joints; 3 MHz for superficial muscles; continuous or pulsed as recommended by clinician
Soft tissue recovery Pulse A or Pulse B modes to support tissue recovery with reduced thermal effect
Tendon and ligament support 1 MHz for deep tendons; 3 MHz for superficial tendons; pulsed for acute, continuous for chronic
Scar tissue care 3 MHz with continuous or Wave mode for superficial scar tissue work
Post-exercise muscle recovery 3 MHz for superficial muscles with Pulse A mode under personal wellness protocol
Shoulder and neck wellness 1 MHz for deeper structures; appropriate mode and intensity per clinician guidance
Knee and back wellness 1 MHz probe for deeper soft tissue support in the knee and lumbar region
Plantar fascia care 1 MHz at the plantar fascia region; intensity and duration per clinician-approved personal protocol

The Digital Ultrasound Device 1-3MHz is ISO & CE marked, confirming compliance with applicable European medical device directives for safety and electromagnetic compatibility. ISO & CE documentation is available on request for regulatory submissions, procurement, and import clearance purposes.

ISO 13485
CE Marked
1
Connect the probes: plug the 1 MHz probe into the 1 MHz port and the 3 MHz probe into the 3 MHz port on the front panel. Both can remain connected simultaneously.
2
Power on: press the power button. The three digital displays will illuminate showing default parameters.
3
Select probe frequency: press the Selector Probe button to choose 1 MHz (deep tissue) or 3 MHz (superficial tissue). Confirm the correct LED illuminates on the right panel.
4
Select output mode: press the appropriate mode button (CONT., PULSE A, PULSE B, or WAVE) as directed by the treatment protocol. The centre display shows the active mode.
5
Set session time: use the Time up/down buttons to set the desired treatment duration in minutes. The left display shows the set time.
6
Apply coupling gel: apply a generous layer of ultrasound coupling gel to the skin at the treatment site before placing the probe.
7
Set intensity: use the Intensity up button to gradually increase the output to the prescribed level in W/cm² as shown on the right display. Monitor the bar-graph indicator.
8
Apply treatment: move the probe slowly and continuously in a circular motion over the treatment area. Never hold the probe stationary during active output.
9
End session: reduce intensity to zero and power off. Remove the probe, clean the probe head and skin to remove coupling gel.
Important: Important note: even when used for home wellness and personal therapy, the first use of this device should be guided by a qualified physiotherapist or healthcare professional who can demonstrate correct technique, appropriate settings, and safe probe movement. Always maintain continuous probe motion during active output. If the ERROR LED illuminates, stop treatment and check coupling gel and probe connection before resuming.
Digital Ultrasound Machine
  • 1 × ULTR 52 Pro main unit (1 & 3 MHz)
  • 1 × 1 MHz treatment probe with cable
  • 1 × 3 MHz treatment probe with cable
  • 1 × AC mains power cable
  • 1 × user manual

Home and personal use

Home wellness programmes Personal therapy use Post-exercise recovery Athlete self-care Home rehabilitation support

Clinical settings

Physiotherapy clinics Rehabilitation centres Sports medicine facilities Pain management clinics Occupational therapy units

B2B distribution

Medical and wellness equipment distributors Physiotherapy equipment suppliers Healthcare and wellness retailers Hospital procurement teams
General Handling

✓ Handle probe heads with care; avoid dropping or mechanical shock as this can damage the piezoelectric crystal. ✓ Place the unit on a stable, flat, dry surface during operation and route cables to prevent trip hazards. ✓ Inspect both probe cables, connectors, and front-panel output ports before each use session. ✓ Store probes in the side holders provided; never tightly wrap cables around probe handles. ✓ Store the unit in a cool, dry environment away from direct sunlight when not in use.

Electrical Safety

✓ Connect to a correctly rated mains supply (110V or 220V) matching the unit's label specification. ✓ Never operate with a damaged power cable, plug, or probe cable; replace before use. ✓ Switch off and disconnect from mains before connecting or disconnecting probe cables. ✓ Do not use near water or in wet environments; keep all liquid away from the unit, displays, and ports. ✓ Do not open the unit casing; refer all servicing to qualified technical personnel.

Patient Safety

âš  Always keep the probe in slow, continuous movement during active output; a stationary probe causes tissue burns and periosteal damage. âš  If the ERROR LED illuminates during treatment, stop immediately and check coupling gel coverage and probe connection before resuming. âš  Always start at the lowest intensity setting and increase gradually; never begin at high intensity. âš  Stop use immediately if burning, sharp pain, or unusual heat is experienced at the treatment site. âš  Do not treat areas of impaired sensation, open wounds, or infections; do not self-treat undiagnosed conditions.

Cleaning & Maintenance

✓ Wipe probe heads with a clean, soft cloth after each use to remove coupling gel; do not immerse probes in liquid. ✓ Clean the unit casing with a lightly dampened cloth; do not allow liquid to enter any display, button, or port. ✓ Inspect probe faces for chips or pitting; a damaged probe face should be replaced before further use. ✓ For clinical use, schedule periodic output calibration and safety checks per local device maintenance standards. ✓ Keep a record of usage sessions, any faults noted, and maintenance actions taken.

Regulatory notice: this device is CE marked for use in home wellness and personal therapy as well as clinical settings. It must be operated, maintained, and stored in compliance with applicable local regulations. Always read the supplied user manual fully before first use. Consult a qualified healthcare professional before self-treating any injury, pain, or medical condition.

Questions

Frequently Asked Questions

The ULTR 52 Pro is specifically designed with home wellness users in mind. The three independent digital displays make it easy to read all parameters simultaneously without navigating menus. The clear ERROR LED provides immediate feedback when coupling gel needs to be reapplied. The separate Intensity, Mode, and Time control groups prevent accidental parameter changes. While professional guidance for initial setup is recommended, the intuitive layout makes the unit suitable for informed personal therapy use once the correct technique and settings have been established.
The left display shows the session timer in minutes. The centre display shows the currently active treatment mode. The right display shows the output intensity in W/cm². All three update in real time during a session, giving a complete view of all active parameters at once without sharing a single combined screen.
The Error LED illuminates when the unit detects a problem with acoustic coupling between the probe face and the skin. The most common cause is insufficient coupling gel or the probe lifting off the skin surface during treatment. If the Error LED comes on, stop the session, reapply coupling gel generously, ensure the probe is making firm skin contact, and check that the probe cable is properly connected before resuming.
Continuous (CONT.) mode delivers uninterrupted ultrasonic output and produces the most thermal effect, typically suited to chronic conditions where tissue warming is beneficial. Pulse A and Pulse B modes deliver pulsed waveforms at different duty cycles, significantly reducing the thermal component and making them suitable for acute or sensitive conditions. Wave mode provides a modulated output pattern. The appropriate mode depends on the condition being treated and should be selected according to professional guidance.
Yes. ISO and CE marking documentation is available on request through SnapShopHub. Contact our export team with your specific regulatory and import requirements and we will provide the necessary paperwork to support customs clearance and local device registration.
Yes. SnapShopHub supplies single units and bulk quantities for distributors, wellness retailers, physiotherapy equipment suppliers, and procurement teams. Contact us for bulk pricing, lead times, and export shipping options.
No, the frequency cannot be set to 1.5 MHz. The machine supports only 1 MHz and 3 MHz frequency options.
It is used for pain relief, muscle relaxation, and physical therapy treatment.
Yes, it is designed for both home and professional use. Suitable for both professional therapy sessions and personal use.
Yes, the intensity can be increased or decreased according to comfort and treatment requirements from 0.5 to 3.5Wm
Yes, the machine is compact and designed for easy handling and portability. It comes with a carry bag.
It can be used on common pain areas such as back, shoulder, neck, knees, and muscles (as per usage guidelines).
Yes, ultrasound therapy is commonly used to help relieve muscle pain and stiffness.
Yes, ultrasound gel is recommended for proper transmission of ultrasound waves.
Yes, all our machines come with user manuals.
Bulk Enquiry