Therapy Equipments · Ultrasonic Therapy
This computerised ultrasonic therapy machine provides 27 pre-set treatment programmes alongside a fully manual mode, enabling physiotherapists to deliver standardised, evidence-based ultrasound protocols at the press of a button. Both a 1 MHz and 3 MHz probe are included and connect to dedicated output ports at the base of the unit, with active frequency confirmed by front-panel LED indicators. The blue-backlit alphanumeric LCD display shows the programme name, timer countdown, intensity, and mode simultaneously, giving the treating clinician a clear overview of all session parameters at a glance. Six logically grouped front-panel buttons control all functions, and the built-in countdown timer manages session duration automatically within each programme.
The Programme/Mode button cycles through 27 pre-set treatment protocols covering a wide range of musculoskeletal and soft tissue conditions, reducing setup time and supporting consistent clinical delivery.
In addition to the 27 pre-sets, a fully manual mode allows the clinician to set intensity, frequency, mode, and timer independently for bespoke treatment protocols.
The blue-backlit LCD displays the active programme name, timer countdown, intensity level, and current mode simultaneously for comprehensive at-a-glance parameter monitoring.
Dedicated LED indicators on the front panel confirm which probe frequency is active, providing a clear visual cue without needing to reference the LCD screen.
Separate labelled 1 MHz and 3 MHz output sockets at the base of the unit allow both probes to remain connected simultaneously, with frequency toggled via the 1+3MHz button.
Dedicated intensity up and down buttons allow precise, incremental output adjustment during treatment without disrupting probe contact with the patient.
The Pulse/1+3MHz button selects the pulsed output duty cycle, enabling the clinician to switch between continuous and pulsed waveform modes as required by the prescription.
The S/S button initiates or pauses the treatment session and timer with one touch, supporting safe session management without altering any previously set parameters.
| Device type | Computerised ultrasonic therapy unit |
| Programmes | 27 pre-set programmes plus manual mode |
| Frequencies | 1 MHz and 3 MHz (selectable; separate dedicated output ports) |
| Frequency indicators | 1 MHz LED and 3 MHz LED on front panel |
| Display | Backlit alphanumeric LCD (programme name, timer, intensity, mode) |
| Timer | Built-in countdown timer; auto-set by programme or manually adjustable |
| Intensity control | Incremental up/down buttons; displayed on LCD |
| Output modes | Continuous and pulsed (selectable via Pulse button) |
| Output ports | 1 × 1 MHz socket and 1 × 3 MHz socket (bottom panel, labelled) |
| Power supply | Mains AC, 110V / 220V, 50/60 Hz |
| Enclosure | Desktop unit with top-mounted probe holders |
| Intended environment | Professional physiotherapy and rehabilitation clinical settings |
| Control | Function |
|---|---|
| LCD display | Shows programme name, timer countdown, intensity level (W/cm²), and current treatment mode simultaneously |
| 1 MHz LED indicator | Illuminates when the 1 MHz probe is the active output frequency |
| 3 MHz LED indicator | Illuminates when the 3 MHz probe is the active output frequency |
| PROG. / MODE button | Cycles through the 27 pre-set programmes and the manual programme mode |
| TIMER (+) button | Increments the session timer in manual mode; programmes set their own default duration |
| Intensity up button | Increases the ultrasonic output intensity in incremental steps |
| Intensity down button | Decreases the ultrasonic output intensity in incremental steps |
| PULSE / 1+3MHz button | Toggles the active output between 1 MHz and 3 MHz probes, and selects pulsed vs continuous output mode |
| S/S (Start/Stop) button | Initiates or pauses the treatment session and timer countdown |
| 1 MHz output socket (bottom) | Dedicated connection for the 1 MHz ultrasound probe cable |
| 3 MHz output socket (bottom) | Dedicated connection for the 3 MHz ultrasound probe cable |
| Condition / Area | Application / Protocol |
|---|---|
| Musculoskeletal pain management | Pre-set programmes for acute and chronic pain; 1 MHz for deep structures, 3 MHz for superficial tissue |
| Acute soft tissue injuries | Pulsed mode pre-set programmes for ligament, tendon, and muscle injuries to minimise thermal load |
| Tendinopathy and tendinitis | 1 MHz for deep tendons; 3 MHz for superficial; pulsed in acute, continuous in chronic presentations |
| Scar tissue softening | 3 MHz with continuous mode programme for superficial scar remodelling |
| Shoulder and rotator cuff conditions | 1 MHz for periarticular and capsular tissue; appropriate pre-set programme selected by clinician |
| Knee and hip pathology | 1 MHz for joint capsule, ligament, and periarticular soft tissue; pre-set or manual mode |
| Plantar fasciitis | 1 MHz probe at plantar fascia insertion; acute pain pre-set or manual pulsed programme |
| Sports injury rehabilitation | Programme and frequency selected by physiotherapist based on tissue depth and healing stage |
This 27-programme ultrasonic therapy machine is ISO and CE marked, confirming compliance with applicable European medical device directives for safety and electromagnetic compatibility. ISO and CE documentation is available on request for regulatory submissions, hospital procurement, and import clearance purposes.
plug the 1 MHz probe into the 1 MHz output socket and the 3 MHz probe into the 3 MHz socket at the base of the unit.
apply a generous layer of ultrasound coupling gel to the patient's skin at the treatment site before placing the probe head.
use the Intensity up button to increase the output to the prescribed therapeutic level as shown on the LCD display.
Always use under professional guidance. Clinical note: all programme selection, frequency choice, and intensity settings must be prescribed and supervised by a qualified physiotherapist or licensed healthcare professional. Always maintain continuous probe movement during active output. Never hold the probe stationary on the patient's skin as this causes localised periosteal heating and tissue burns.
Clinical settings
Suitable for
B2B distribution
✓ Handle probe heads with care; dropping or mechanical shock to the probe can damage the internal piezoelectric crystal, affecting output accuracy. ✓ Place the unit on a stable, flat, dry surface during operation and route cables safely to prevent trip hazards. ✓ Inspect both probe cables, connectors, and bottom-panel output ports before each session. ✓ Store probes in the top-mounted holders when not in use; never tightly wrap cables around probe handles. ✓ Store the unit in a cool, dry environment away from direct sunlight and moisture when not in clinical use.
✓ Connect to a correctly rated and earthed mains supply (110V or 220V) matching the unit's specification label. ✓ Never operate with a damaged power cable, plug, or probe cable; replace before use. ✓ Switch off and disconnect from mains before connecting or disconnecting probe cables at the base sockets. ✓ Do not use in wet environments or where liquid spillage may reach the unit, buttons, or output ports. ✓ Do not open the unit casing; refer all internal servicing to a qualified biomedical engineer.
âš Always keep the probe in slow, continuous circular movement during active output; a stationary probe will cause localised heating and periosteal burns. âš Confirm adequate coupling gel is applied before starting; the probe must maintain contact throughout treatment. âš Verify that the correct programme, frequency, and intensity are set before pressing Start/Stop. âš Stop treatment immediately if the patient reports burning, sharp pain, or unusual heat at the treatment site. âš Do not treat over areas where the patient cannot reliably report sensation, as thermal damage may occur without warning.
Wipe both probe heads with a clean, soft cloth after each patient use to remove residual coupling gel; do not immerse probes in liquid. ✓ Clean the unit casing and top panel with a cloth lightly dampened with a mild disinfectant; do not allow liquid into the LCD screen, buttons, or base output ports. ✓ Inspect probe faces regularly for chips or pitting; a damaged probe face must be replaced before further clinical use. ✓ Schedule periodic output calibration and electrical safety testing by a qualified biomedical engineer in line with local clinical engineering standards. ✓ Maintain a service log recording calibration dates, probe inspections, faults noted, and corrective actions taken.
Regulatory notice: this device is for professional clinical use only. It must be operated, maintained, and stored in compliance with local medical device regulations. Output calibration should be verified periodically per local clinical engineering standards. Always follow the instructions provided in the supplied user manual and consult your regional regulatory authority for applicable compliance and registration requirements.
Questions
Leave your details and we'll call you back about 1 & 3 MHz Ultrasonic Therapy Machine- 27 Program.
1 & 3 MHz Ultrasonic Therapy Machine- 27 Program
Programmes: 27 pre-set programmes plus manual mode
Prefer a call instead? Request a callback
In order to provide you a personalized shopping experience, our site uses cookies. By continuing to use this site, you are agreeing to our cookie policy.
Don't have an account yet? Sign up
No items in your cart. Go on, fill it up with something you love!
Start Shopping Now
1 & 3 MHz Ultrasonic Therapy Machine- 27 Program
1 & 3 MHz Ultrasonic Therapy Machine- 27 Program