Woodpecker I Sensor RVG Size 1 Digital Dental X-Ray Sensor

$987.99
Ultra-slim Size 1 design: : 4.4 mm thin profile with rounded corners for improved patient comfort, ideal for pediatric patients and anterior imaging.
IP68 waterproof construction: fully sealed for safe immersion in approved cold-chemical disinfectants, supporting strict clinical infection control.
Instant image acquisition: high-resolution digital images appear within approximately 3 seconds of exposure, eliminating film processing entirely.
AI-Dental software included: automatically identifies permanent and deciduous teeth and assists with image analysis for more efficient clinical review.
Top Highlights
Brand / Model
Woodpecker i-Sensor H1 (Size 1)
Sensor Thickness
4.4 mm
Active Imaging Area
20 × 30 mm
Theoretical Resolution
25 lp/mm
Protection Rating
IP68
Cable
2.7 m · 80,000 bend cycles tested
Best For
Pediatric · Anterior Imaging
Intended Use
Professional Dental Diagnostic Imaging (Rx)
Quality
CE Marked, ISO 13485
Buy Now
Guaranteed Safe And Secure Checkout
Visa Mastercard American Express Discover PayPal PayU Razorpay Stripe

The Woodpecker i-Sensor H1 is a Size 1 professional digital intraoral X-ray sensor designed for practices that routinely perform pediatric imaging, anterior periapical radiography, or work with patients who have smaller oral anatomy. At just 4.4 mm thick with a 20 × 30 mm active imaging area, it is the smaller sibling to the Size 2 i-Sensor H2. Its IP68-rated CNC-fused housing allows safe immersion in approved cold-chemical disinfectants, and the 2.7 m USB cable is tested for over 80,000 bend cycles for long-term reliability. The included AI-Dental software adds automatic tooth identification and intelligent image analysis tools not found on standard RVG sensors.

25 lp/mm theoretical resolution
4.4 mm slim profile
IP68 Waterproof rated
AI Dental analysis software

Key features

1 4.4 mm Slim Profile

Thinner than many competing sensors, reducing intraoral discomfort particularly for pediatric patients and those with limited mouth opening.

2 IP68 Waterproof

Safe for full immersion in approved cold-chemical disinfectants, enabling thorough sensor disinfection between patients.

3 AI-Dental Software

Automatically identifies permanent and deciduous teeth; assists clinicians with intelligent image analysis tools directly on the captured radiograph.

4 80,000 Bend Cycle Cable

Reinforced 2.7 m USB cable tested for long-term clinical durability in high-volume practice environments.

Sensor Size Size 1 (H1)
Active Imaging Area 20 × 30 mm
Theoretical Resolution 25 lp/mm
Effective Resolution Greater than 12 lp/mm
Pixel Size 20 μm
Sensor Thickness 4.4 mm
Cable Length 2.7 m
Protection Rating IP68
Connection USB Direct
Image Display Speed Approximately 3 seconds
1
Connect: Connect the sensor to a compatible USB port on the imaging workstation.
2
Launch Software: Open the AI-Dental software or your TWAIN-compatible imaging platform before beginning the exposure.
3
Apply Barrier: Cover the sensor with a fresh disposable barrier sleeve before every patient.
4
Position: Place the sensor parallel to the tooth using a compatible positioning system and confirm the active area is correctly aligned.
5
Expose: Activate the X-ray generator at the appropriate exposure setting for the selected tooth and film speed equivalent.
6
Review: The image appears within approximately 3 seconds. Use the AI-Dental software tools to review, enhance, and annotate as needed.
Woodpecker RVG Size 1 i sensor
  • 1 x Woodpecker i-Sensor H1 (Size 1) with 2.7 m USB Cable
  • 1 x Software Installation Media (AI-Dental)
  • 1 x Power Adapter
  • 1 x User Manual

Clinicians

General Dentists Paediatric Dentists Endodontists Periodontists Orthodontists

Settings

General Dental Clinics Paediatric Dental Practices Dental Hospitals Dental Colleges

Procedures

Pediatric Radiography Anterior Periapical Imaging Caries Detection Endodontic Working Length Periodontal Bone Assessment Root Canal Obturation Check
Barrier Sleeve Every Patient

Always fit a fresh disposable barrier sleeve before intraoral positioning to maintain barrier infection control.

Cold Disinfect Only

Disinfect using approved cold-chemical disinfectants. The IP68 rating allows safe immersion. Never autoclave.

Protect the Cable

Store the cable loosely coiled and avoid tight bends near the sensor housing to protect internal wiring.

Inspect Regularly

Check the cable and housing regularly for signs of wear, cracking, or physical damage and remove from service if damaged.

Professional diagnostic use only: This is a prescription-grade professional dental diagnostic device intended exclusively for use by qualified dental professionals. Images produced support clinical diagnosis but do not replace a comprehensive clinical examination. Never autoclave. Always apply a fresh disposable barrier sleeve for each patient. Cold-chemical disinfection only. Comply with current infection control guidelines and regulatory requirements for your destination market. Product documentation available on request.

Questions

Frequently Asked Questions

RVG (RadioVisioGraphy) is a digital dental X-ray sensor that captures intraoral radiographs electronically and displays diagnostic images almost instantly, eliminating the need for film and chemical processing.
Size 1 is particularly well suited for pediatric patients, anterior periapical imaging, patients with narrower dental arches, and those with limited mouth opening. For routine adult posterior and bitewing imaging, the Size 2 (H2) provides a larger active imaging area.
The AI-Dental software automatically identifies and labels permanent and deciduous teeth on captured radiographs, and provides intelligent image analysis assistance to support clinical review. It runs on Windows 7 through 11 and integrates with TWAIN-compatible imaging platforms.
The sensor displays captured images in approximately 3 seconds, allowing immediate chairside review without any processing delay.
No. Never autoclave or dry-heat sterilize the sensor. The IP68 rating allows safe immersion in approved cold-chemical disinfectants for disinfection between patients. Always use a fresh disposable barrier sleeve during procedures.
No. The supplied AI-Dental software and TWAIN drivers are designed for Windows operating systems only (Windows 7 through 11). macOS is not supported.
The H1 (Size 1) has a smaller 20 × 30 mm active area and 4.4 mm thickness, making it better suited for pediatric and anterior imaging. The H2 (Size 2) has a larger 26 × 36 mm active area at 4.5 mm thickness, covering adult posterior and bitewing imaging more effectively. Both share the same resolution specifications and IP68 rating.