Surgical Equipment · Electrosurgery · Dermatology

Healocator Mini Electro Surgical Cautery

$249.19
High precision performance: delivers controlled high-frequency energy for accurate tissue treatment while helping minimise impact on surrounding healthy tissue.
Effective hemostasis: seals blood vessels during procedures to reduce blood loss and maintain a clear surgical field.
Multiple treatment modes: supports desiccation, fulguration, coagulation, and epilation for a wide range of minor surgical and dermatology procedures.
Compact portable design: fits easily into clinics and outpatient settings while providing convenient handling and manoeuvrability.
Top Highlights
Brand
Healocator
Model
Mini Electrosurgical Unit
Generator Type
Spark Gap High-Frequency Generator
Operating Modes
Unipolar and Bipolar
Cutting Output
20 W (Low) / 40 W (High)
Bipolar Output
30 W
Power Input
Dual Voltage 110 V / 220 V
Quality
CE Marking ISO 13485:2016
Buy Now
Guaranteed Safe And Secure Checkout
Visa Mastercard American Express Discover PayPal PayU Razorpay Stripe

The Healocator Mini Electrosurgical Unit provides precise tissue cutting and coagulation for minor surgical and dermatological procedures. Its spark gap high-frequency generator delivers consistent performance for desiccation, fulguration, coagulation, and epilation, while the compact design makes it suitable for clinics, outpatient facilities, dermatology practices, and cosmetic treatment centres.

40 W Max cutting output
30 W Bipolar output
4 modes Desicc · Fulg · Coag · Epilat
110/220 V Dual-voltage

Pricing: pricing varies by order volume and destination market. Contact us for current unit and bulk export pricing, or for a formal quotation for clinic, hospital, or distributor procurement.

Usage: for supply to qualified healthcare professionals, licensed clinics, hospitals, and authorised distributors only. This surgical cautery machine is intended exclusively for professional minor electrosurgical procedures and is not suitable for deep tissue coagulation or major surgery.

Key features

1 High-precision performance

Controlled energy delivery for accurate treatment of superficial tissues while protecting adjacent healthy tissue.

2 Effective hemostasis

Seals blood vessels quickly to improve visibility and reduce blood loss throughout the procedure.

3 Spark gap generator

Stable high-frequency output for dependable performance across available power settings.

4 Unipolar and bipolar operation

Clinicians can select the appropriate mode for different clinical applications.

5 Multi-functional treatment

Supports desiccation, fulguration, coagulation, and epilation with a single device.

6 Compact portable design

Saves workspace and allows convenient positioning in clinics and outpatient treatment rooms.

7 Dual-voltage compatibility

Operates on both 110 V and 220 V power supplies for greater installation flexibility.

8 Foot switch activation

Enables hands-free energy activation during procedures for improved sterility and control.

Product Name Healocator Mini Electrosurgical Unit
Product Category Surgical Equipment
Generator Technology Spark Gap High-Frequency Generator
Operating Modes Monopolar Low, Monopolar High, Bipolar
Cutting Output (Low) 20 Watts
Cutting Output (High) 40 Watts
Bipolar Output 30 Watts
Power Input Dual Voltage 110 V / 220 V
Clinical Functions Desiccation, Fulguration, Coagulation, Epilation
Professional Use Qualified healthcare professionals only

The Healocator Mini Electrosurgical Unit is supported by ISO 13485:2016 certification and CE Marking, demonstrating compliance with recognised medical device quality management and applicable regulatory requirements for professional healthcare use.

CE Marking
ISO 13485:2016
1
Prepare: Verify the unit is correctly connected to an appropriate 110 V or 220 V power supply and select the required electrode or accessory.
2
Position: Place the inactive plate securely on the patient before performing any unipolar procedure. Bipolar procedures require only the supplied tweezers.
3
Select mode: Choose the appropriate operating mode and treatment accessory for the intended clinical procedure.
4
Adjust output: Begin with the lowest power setting and gradually increase output according to tissue response.
5
Operate: Activate the current using the supplied foot switch while performing the planned procedure.
6
Complete: Switch off the unit before removing or changing electrodes or needles.
7
Clean and sterilise: Sterilise reusable accessories using standard clinical autoclave protocols before the next patient.
Healocator Mini Electro Surgical Cautery
  • 1 × Healocator Mini Electrosurgical Unit
  • 1 × Surgical Handle
  • 5 × Reusable Electrodes
  • 1 × Electrolysis Needle
  • 1 × Foot Switch
  • 1 × Inactive Plate (P. Plate)
  • 1 × Tweezer with Cable (Bipolar)
  • 1 × Main Power Cable
  • 1 × Operating Manual
  • 1 × Power Socket Adapter

Clinical Settings

Dermatology clinics Cosmetic clinics Skin surgery practices General medical practices Outpatient facilities

Typical Procedures

Benign skin lesion removal Wart and skin tag treatment Superficial tissue destruction Coagulation and desiccation Fulguration Epilation Bleeding control
Feature
Unipolar Mode This product
Bipolar Mode
Current path
Travels through the patient to the inactive plate
Travels only between the tweezer tips
Inactive plate required
Yes, secure contact required
No inactive plate needed
Included accessory
Inactive Plate (P. Plate)
Bipolar Tweezers with Cable
Typical applications
Cutting and coagulation of superficial tissue
Localised bipolar coagulation
Power off before changing electrodes

Switch off and unplug the device before changing electrodes or electrolysis needles.

Autoclave after every patient

Sterilise the surgical handle, reusable electrodes, and tweezers using approved autoclave procedures after every patient.

Secure inactive plate

Ensure the inactive plate maintains secure contact with the patient throughout all unipolar procedures.

Minor procedures only

Not suitable for deep tissue coagulation or major surgery. Intended only for minor electrosurgical procedures.

Clean storage

Store the equipment in a clean, dry clinical environment when not in use.

Qualified professionals only

This device is intended exclusively for use by qualified healthcare professionals.

Avoid flammable preparations

Keep away from flammable liquids, pooled alcohol-based skin preparations, and combustible gases.

No pacemaker patients

Do not use on patients with pacemakers or other implanted active electronic devices.

Questions

Frequently Asked Questions

An electrocautery machine is a medical device that uses high-frequency electrical energy to cut tissue, coagulate blood vessels, control bleeding, and perform selected superficial surgical procedures.
Unipolar mode passes current through the patient to an inactive plate, while bipolar mode passes current only between the tips of the bipolar tweezers and does not require an inactive plate.
It is intended for minor electrosurgical procedures including desiccation, fulguration, coagulation, epilation, superficial tissue treatment, and benign skin lesion management.
Yes. This electrocautery machine for dermatology is designed for professional dermatology, cosmetic, skin surgery, and outpatient clinical procedures.
Yes. The supplied electrodes are reusable and should be cleaned and sterilised using standard autoclave procedures between patients.
Yes. The unit operates on both 110 V and 220 V power supplies and includes a compatible power socket adapter.
No. The inactive plate is required only during unipolar procedures. Bipolar procedures performed with the supplied tweezers do not require patient grounding.
Always begin at the lowest setting and gradually increase the output according to tissue response while following appropriate clinical practice.
No. Because the spark gap generator can create an ignition source, the device must not be operated in the presence of flammable liquids, pooled alcohol preparations, or combustible gases.
Yes. The package includes the main unit, surgical handle, reusable electrodes, electrolysis needle, foot switch, inactive plate, bipolar tweezers with cable, power cable, operating manual, and power socket adapter.
Bulk Enquiry